Rochester Sensors|FOZTLL250-04B
ROCHESTER SENSORS TLL250 / TLL251 Hydrostatic Liquid Level Sensor
Tax excluded. Shipping calculated at checkout
GST (10%) is calculated at checkout. Tax invoices provided with all orders.
Ships ex WA Stock
Held in stock in Western Australia and dispatched via overnight freight. Live delivery times to your address are shown at checkout; freight is quoted for remote sites.
Ships from Brisbane warehouse. Standard delivery 2-5 business days Australia-wide.

DEEP-TANK LEVEL BY HYDROSTATIC PRESSURE
Submersible hydrostatic level sensor for deep tanks. Calibrated on site, 1" BSPT thread, compatible with diesel, petrol, kerosene and water. TLL250 gives 0-5V output, TLL251 gives 4-20mA. Not suitable for fuels containing toluene.
Hydrostatic reading for tall tanks
A submersible hydrostatic sensor reads level by the head of liquid above it, so it handles deep and tall tanks that a fixed rod probe cannot. Choose up to 4m or up to 10m.
One family, two outputs
TLL250 gives a 0-5V output and TLL251 gives 4-20mA, both compatible with diesel, petrol, kerosene and water. Calibrate on site to suit your tank. Note it is not suitable for fuels containing toluene.
Features & Benefits
Key Features
- Hydrostatic measurement for deep tanks
- Compatible with diesel, petrol, kerosene and water
- Calibrate on site
- 1" BSPT thread
- TLL250 = 0-5V output, TLL251 = 4-20mA output
- Maximum liquid level of 4m or 10m
Benefits
- Reads tall tanks a fixed probe cannot reach
- Spans fuel and water service from one family
- On-site calibration tunes it to your tank and fluid
| Type | Hydrostatic submersible level sensor |
| Thread | 1" BSPT |
| Output | 0-5V (TLL250) or 4-20mA (TLL251) |
| Max liquid level | 4m or 10m (per variant) |
| Calibration | On site |
| Suitable for | Diesel, petrol, kerosene, water |
| Not suitable for | Fuels containing toluene |
Shipping & Dimensions
Dispatched from our WA stock via overnight freight. Live delivery times to your address are shown at checkout; freight quoted for remote sites.
Downloads
Compatible Products
Frequently Asked Questions
Can't find your answer?
Contact UsWhich fluids is it suitable for?
Diesel, petrol, kerosene and water. It is not suitable for fuels that contain toluene - contact our team if you are unsure about your fuel blend.
What is the difference between TLL250 and TLL251?
TLL250 provides a 0-5V output and TLL251 provides a 4-20mA output. The 4m and 10m options set the maximum liquid level the sensor reads.
Does it need calibration?
Yes, it is calibrated on site to your tank and fluid. Our team can advise on the set-up.