Power Generation - Generator Fuel Storage
Backup generators are only as reliable as their fuel supply. GO Fill provides bulk diesel storage from 5,500L to 110,000L with continuous tank monitoring, automated day tank controllers, and fuel quality management systems that ensure clean diesel is always ready when the power goes out.
For data centres, hospitals, and critical infrastructure, fire-rated tanks (UL2085) enable indoor storage with halved separation distances — keeping fuel close to generators without compromising safety.
Reliable Fuel Supply
Bulk Storage for Generator Infrastructure
Organize content into multiple columns to share useful information to your customers about your products, values...

GO STORE Tanks
5,500L to 16,000L for single-generator installations. Full-height pump bay, overfill protection, and 600mm manway. Ideal for commercial buildings, shopping centres, and mid-scale facilities.

GO CON Containerised
12,000L to 110,000L for data centres, hospitals, and multi-generator sites. Container footprint for space efficiency, multi-tank linking for scalability, DN80 fire-safe valves.

Fire Rated Tanks
UL2085 fire-rated for indoor installation adjacent to generators. FRL 240/240/240 rating halves AS1940 separation distances. Essential for space-constrained sites like basements and plant rooms.
Monitoring & Quality
Keep Fuel Ready for When It Matters
Organize content into multiple columns to share useful information to your customers about your products, values...

Tank Gauges & Monitoring
Continuous level monitoring with 4–20mA output for BMS/SCADA integration. Know your diesel inventory remotely and automate reorder notifications before levels drop below critical thresholds.

Day Tank Controllers
OLE T4000 day tank controllers automate diesel transfer from bulk storage to generator day tanks. Maintains day tank level without manual intervention — critical for 24/7 unattended sites.

Fuel Quality Management
Stored diesel degrades over time. Desiccant breathers prevent moisture ingress, water-separation filters remove contamination, and fuel polishing services restore degraded diesel to spec.

Tank Breathers
Donaldson TRAP desiccant breathers remove moisture from tank headspace air. Essential for standby fuel that sits for months between use — prevents water accumulation and diesel bug.

Always-Ready Fuel Supply
Backup generators fail most often because of fuel problems — empty tanks, water contamination, or blocked filters. Continuous monitoring, desiccant breathers, and automated day tank controllers eliminate these failure modes.

Indoor Installation with Fire-Rated Tanks
UL2085 fire-rated tanks enable indoor diesel storage in basements, plant rooms, and rooftops — keeping fuel close to generators while meeting fire safety requirements.
Power Generation FAQ
Use this text to share information about your product or shipping policies.
How long can diesel be stored for backup generators?
With proper fuel quality management (desiccant breather, water-separation filter, sealed tank), diesel can be reliably stored for 6–12 months. Without these measures, water contamination and microbial growth can render stored diesel unusable within 3–6 months. For critical applications, we recommend annual fuel testing and polishing.
Can I install a fuel tank indoors?
Yes, with a UL2085 fire-rated tank. AS1940 Clause 5.6.2(c) permits indoor storage of diesel and petrol in fire-rated tanks. The FRL 240/240/240 rating halves the required separation distances compared to standard tanks, making indoor installation practical in basements and plant rooms.
What is a day tank controller?
A day tank controller (e.g., OLE T4000) automatically maintains the fuel level in a small day tank connected to the generator. When the day tank level drops, the controller activates a transfer pump to refill from bulk storage. This ensures the generator always has fuel without manual checking or filling.