PIUSI PANTHER EX 56 ATEX TRANSFER PUMP

ATEX Zone 1 cast-iron transfer pump. 56 lpm at 240V AC, continuous duty, feet-mounted. Suits petrol, diesel, kerosene in hazardous-area installations.

Manufacturer Code F00580030
Model Panther EX 56 (Feet)
Pump Type Self-priming vane with bypass
Flow Rate 56 l/min (14.7 GPM)
Voltage 230V / 50Hz (compatible 240V AU)
View all
56
L/MIN FLOW
ATEX
ZONE 1 / 2
240V
AC CONTINUOUS
CAST IRON
BODY
The transfer pump that scales from drum to bowser
Same Panther, hardened for petrol

The transfer pump that scales from drum to bowser

The Panther 56 is the most-installed mid-size pump in the Piusi range because it just works. The Panther EX 56 takes the same proven cast-iron architecture and adds ATEX II 2 G certification - which means you can legally handle petrol, kerosene, and other flammable liquids in a Zone 1 / Zone 2 hazardous area without re-engineering your installation around a different pump.

56 L/MIN
FLOW RATE
Bolt-down installation for fixed transfer stations
Why feet-mounted

Bolt-down installation for fixed transfer stations

The feet version (F00580030) is the right pick when you're plumbing the pump into a fixed installation - tank-side transfer station, wall mount, or custom skid. Removable feet bolt to four standard mounting points, and you get a magnetic ON/OFF switch positioned for easy access. The drum version (F00580010) ships with a telescopic suction tube and is the choice for direct 200L drum / IBC mounting - speak to us if that's what you actually need.

BOLT DOWN
INSTALL

Features & Benefits

Key Features

  • ATEX II 2 G Ex d IIA T4 Gb explosion-proof rating for Zone 1 hazardous areas
  • 56 l/min continuous duty at 240V AC, 500W single-phase motor
  • Cast-iron pump body with sintered-steel rotor and Viton seals
  • Magnetic ON/OFF switch and integrated bypass valve
  • 1" BSP inlet and outlet for standard fuel-line plumbing
  • Suitable for diesel, petrol, and kerosene
  • Removable feet for permanent bolt-down installation
  • 12-month Piusi manufacturer warranty plus ATEX/IECEx certificate
Performance
Flow Rate 56 l/min (14.7 GPM)
RPM 2800
Flow Rate
56 l/min (14.7 GPM)
RPM
2800
Physical
Inlet Thread 1" BSP
Outlet Thread 1" BSP
Body Material Cast iron
Mounting Feet (removable, bolt-down)
Weight 12.4 kg
Inlet Thread
1" BSP
Outlet Thread
1" BSP
Body Material
Cast iron
Mounting
Feet (removable, bolt-down)
Weight
12.4 kg
Electrical
Voltage 230V / 50Hz (compatible 240V AU)
Power 500 W
Max Current 2.3 A
Voltage
230V / 50Hz (compatible 240V AU)
Power
500 W
Max Current
2.3 A
Wetted Parts
Rotor Sintered steel
Vanes Technopolymer
Seal Viton
Shaft Steel
Rotor
Sintered steel
Vanes
Technopolymer
Seal
Viton
Shaft
Steel
Compliance
Pump Type Self-priming vane with bypass
ATEX Marking II 2 G Ex d IIA T4 Gb
Country of Origin Italy
Warranty 12 months
Pump Type
Self-priming vane with bypass
ATEX Marking
II 2 G Ex d IIA T4 Gb
Country of Origin
Italy
Warranty
12 months
General
Manufacturer Code F00580030
Model Panther EX 56 (Feet)
Duty Cycle Continuous (S1)
Switch Magnetic ON/OFF
Fluid Compatibility Diesel, petrol, kerosene
Packaging 400 x 240 x 300 mm
Manufacturer Code
F00580030
Model
Panther EX 56 (Feet)
Duty Cycle
Continuous (S1)
Switch
Magnetic ON/OFF
Fluid Compatibility
Diesel, petrol, kerosene
Packaging
400 x 240 x 300 mm

Shipping & Dimensions

12.4 kg
Weight

Ships from Brisbane in original Piusi packaging. 400 x 240 x 300 mm carton.

Compatible Products

Frequently Asked Questions

Can't find your answer?

Contact Us
What's the difference between the Panther 56 and the Panther EX 56?

The Panther 56 is rated for diesel only. The Panther EX 56 carries ATEX II 2 G certification for petrol, kerosene, and other flammable liquids in Zone 1 / Zone 2 hazardous areas. Same pump architecture, hardened for hazardous service.

Is this the feet or drum version?

Feet version (F00580030). Comes with removable mounting feet for bolt-down installation. The drum version (F00580010 in Piusi's catalogue) ships with a drum connector and nozzle holder for IBC / 200L drum mounting - speak to us if that's what you need.

Why ATEX for diesel?

Diesel itself is not flagged as Zone 1, but if you're sharing a yard, workshop, or storage area with petrol or other flammable hydrocarbons, your hazardous-area classification may require ATEX-certified equipment across the whole installation. Many WHS-conscious sites standardise on ATEX as a future-proofing measure.

Does it run continuously or have a duty cycle?

Continuous duty (S1). You can run it back-to-back for shift-long fills without thermal cut-out, unlike the Cube cabinet dispensers which have a 30-minute on/off cycle.

What flow meter pairs with it?

For ATEX-compliant metering, pair with the Piusi K600 ATEX or K33 ATEX mechanical meter. Non-ATEX meters cannot legally be used in the same Zone 1 installation.

Does it come with a nozzle and hose?

No - this is the pump-only version. Speak to us about matched ATEX-rated nozzles, hoses, and suction kits to build a complete petrol or diesel transfer station.